The PRT: Particle Tracking Model Pane(s) are on the MODFLOW Packages and Programs dialog box under PRT: Particle Tracking Model. They are used to specify the properties of individual PRP packages in a PRT model.
The locations of the release points are specified on the PRP: Particle Release Point Package Pane of the Object Properties Dialog Box.
The PRP Package offers multiple ways to specify particle release times. Particle release times may either be provided explicitly, relative to the simulation start time, or configured relative to the time discretization of stress periods via period block settings. When multiple ways of specifying release times are used together, the resulting set of release times is the union of the times specified by each method.
Each PRP pane has three tabs.
Options:
•EXIT_SOLVE_TOLERANCE: the convergence tolerance for iterative solution of particle exit location and time in the generalized Pollock’s method. The variable being solved for varies from 0 to 1. A tolerance of 0.00001 works well for many problems, but the value that strikes the best balance between accuracy and runtime is problem-dependent. In MODFLOW, the default value of this variable is 1E-5.
•EXTEND_TRACKING: indicates that particles should be tracked beyond the end of the simulation’s final time step (using that time step’s flows) until particles terminate or reach a specified stop time. By default, particles are terminated at the end of the simulation’s final time step.
•Track Output: is used to specify that track files will be created for the TRACK FILEOUT and/or TRACKCSV FILEOUT options. Note that track files can also be specified in the PRT: Particle Tracking Model pane.
•STOPTIME: real value defining the maximum simulation time to which particles in the package can be tracked. Particles that have not terminated earlier due to another termination condition will terminate when simulation time STOPTIME is reached. If the last stress period in the simulation consists of more than one time step, particles will not be tracked past the ending time of the last stress period, regardless of STOPTIME. If the EXTEND_TRACKING option is enabled and the last stress period in the simulation is steady-state, the simulation ending time will not limit the time to which particles can be tracked, but STOPTIME and STOPTRAVELTIME will continue to apply. If STOPTIME and STOPTRAVELTIME are both provided, particles will be stopped if either is reached.
•STOPTRAVELTIME: real value defining the maximum travel time over which particles in the model can be tracked. Particles that have not terminated earlier due to another termination condition will terminate when their travel time reaches STOPTRAVELTIME. If the last stress period in the simulation consists of more than one time step, particles will not be tracked past the ending time of the last stress period, regardless of STOPTRAVELTIME. If the EXTEND_TRACKING option is enabled and the last stress period in the simulation is steady-state, the simulation ending time will not limit the time to which particles can be tracked, but STOPTIME and STOPTRAVELTIME will continue to apply. If STOPTIME and STOPTRAVELTIME are both provided, particles will be stopped if either is reached.
•STOP_AT_WEAK_SINK: is a text keyword to indicate that a particle is to terminate when it enters a cell that is a weak sink. By default, particles are allowed to pass though cells that are weak sinks.
•ISTOPZONE: integer value defining the stop zone number. If cells have been assigned IZONE values in the GRIDDATA block, a particle terminates if it enters a cell whose IZONE value matches ISTOPZONE. An ISTOPZONE value of zero indicates that there is no stop zone. The default value is zero.
•DRAPE: is a text keyword to indicate that if a particle’s release point is in a cell that happens to be inactive at release time, the particle is to be moved to the topmost active cell below it, if any. By default, a particle is not released into the simulation if its release point’s cell is inactive at release time. Note that DRAPE does not apply to attempted release into a cell for which IDOMAIN <= 0, which is considered not to exist in the simulation. Attempted release into a such a cell results in an error.
•DRY_TRACKING_METHOD: is a string indicating how particles should behave in dry-but-active cells (as can occur with the Newton formulation). The value can be “DROP”, “STOP”, or “STAY”. The default is “DROP”, which passes particles vertically and instantaneously to the water table. “STOP” causes particles to terminate. “STAY” causes particles to remain stationary but active.
•RELEASE_TIME_TOLERANCE: real number indicating the tolerance within which to consider consecutive release times coincident. Coincident release times will be merged into a single release time. The default is ε × 1011, where ε is machine precision.
•RELEASE_TIME_FREQUENCY: real number indicating the time frequency at which to release particles. This option can be used to schedule releases at a regular interval for the duration of the simulation, starting at the simulation start time. The release schedule is the union of this option, the RELEASETIMES block, and PERIOD block RELEASESETTING selections. If none of these are provided, a single release time is configured at the beginning of the first time step of the simulation’s first stress period.
•COORDINATE_CHECK_METHOD: approach for verifying that release point coordinates are in the cell with the specified ID. Possible values are NONE and EAGER. By default, release point coordinates are checked at release time, i.e. EAGER.
Release Times:
•On the Release Times tab, the user can specify times at which particles are to be released. ModelMuse automatically pecifies the beginning of the first stress period as a release time when a PRP packages is first created. If no release times and no release period data are specified, MODFLOW will release particles at the beginning of every stress period.
Release Period Data:
The user can specify a variety of ways to determine when the locations of particles are to be released in addition to times specified on the Release Times tab. The times at which particles will be released will be determined by combining all the methods that are specified. If no PERIOD block is specified for any period, a single particle is released from each release point at the beginning of the simulation.
•Starting time: This is the beginning time of the first stress period to which the data in the row will apply.
•Ending time: This is the ending time of the last stress period to which the data in the row will apply.
•All Steps: If the check box in a row is checked, particles will be released for every time step in the specified stress period or periods.
•First Step: If the check box in a row is checked, particles will be released for the first time step in the specified stress period or periods.
•Last Step: If the check box in a row is checked, particles will be released for the last time step in the specified stress period or periods.
•Step Frequency: If a number is specified, particles will be released at the specified step frequency in the specified stress period or periods.
•Steps: If a comma-separated list of step numbers is specified, particles will be released in the specified stress period or periods.