The Lake package simulates lakes whose elevations can rise or fall due to interaction with groundwater. The pane for this package is on the MODFLOW Packages and Programs dialog box under Head Dependant Flux.

If the Lake package and either Groundwater Transport (GWT) or Groundwater Energy Transport (GWE) is also active, the Lake Transport (LKT) or the Lake Energy Transport (LKE) packages respectively will activated automatically.

If the Print stage checkbox is checked, the list of lake stages will be printed to the listing file for every whenever head is printed.

If the Save binary Lake stage file (.lk_stg) checkbox is checked, the lake stages will be saved in a binary file with the extension ."lk_stg."

If the Save binary lake budget file (.lk_bud) checkbox is checked, the lake flow budget information will be saved in a binary file with the extension ."lk_bud."

Surfaced depression depth (SURFDEPTH) SURFDEPTH is used to reduce numerical oscillations.

Use implicit formulation (IMPLICIT): activates the implicit formulation. With this option each lake stage is solved as an additional unknown in the groundwater flow matrix, instead of by the default substitution-iteration solver. The implicit formulation typically converges in far fewer outer iterations for steady-state and strongly coupled lakes and can solve problems for which the default formulation fails to converge. Converged results are equivalent to the default formulation. The implicit formulation makes the coefficient matrix asymmetric and therefore requires the BICGSTAB linear acceleration in the Iterative Model Solution (IMS). Each lake must have at least one groundwater connection when the IMPLICIT option is active because the implicit formulation solves the lake stage through its lakebed seepage; the program will terminate with an error if a lake with no groundwater connections is specified with the IMPLICIT option. If a lake stage becomes too poorly conditioned to solve as a matrix unknown, which can happen for a weakly connected or disconnected lake, that lake is solved automatically by the default substitution solver instead, so the implicit formulation remains as robust as the default formulation. The Newton formulation is recommended for lakes that may become perched (disconnected from the aquifer), because results obtained with the standard rewetting (REWET) capability can otherwise differ between the two approaches.

See also: LAK: Lake Package for MODFLOW 6 Pane on the Object Properties dialog box