6.Select Data|Edit Data Sets… and enter the following values for the default formulas.

 

Data Set

Default Formula

Kx

1.5E-5

Ky

1.5E-5

Kz

1.5E-7

Porosity

0.22

Specific_Storage

0

Longitudinal_Dispersivity

2000

Horizontal_Transverse_Dispersivity

50

Vertical_Transverse_Dispersivity

50

Initial_Head

380

Chemistry_Initial_Solution

2

Chemistry_Initial_Equilibrium_Phases

2

Chemistry_Initial_Surface

2

Chemistry_Initial_Exchange

2

 

7.In this example, the bottom layer to the east of an X coordinate of 48000 is inactive. To set this, draw an object on the top view of the model enclosing this area (fig. 53). In the Object Properties dialog box, leave the Elements radio button checked, set the object’s Name to “Inactive_Area”, check the Set values of enclosed elements checkbox and set the Higher Z-coordinate to 100. On the Data Sets tab, check the checkbox for the Active data set (under "Required|Hydrology") and set its formula to “False.” After closing the Object Properties dialog box, color the grid with the Active data set and set the selected layer to the bottom layer. Check that the inactive area is restricted to the bottom layer (fig. 53). Using the mouse cursor, right click on the top view of the model and select Hide Selected Objects to hide the “Inactive_Area” object.

 

See caption

Figure 53. Active (blue) and inactive (red) areas in example.