Online Guide to MODFLOW-2005

SWR1 List Utility Subroutine SSWRLSTRD

Hide Navigation Pane

SWR1 List Utility Subroutine SSWRLSTRD

Previous topic Next topic No directory for this topic Expand/collapse all hidden text  

SWR1 List Utility Subroutine SSWRLSTRD

Previous topic Next topic Topic directory requires JavaScript JavaScript is required for expanding text JavaScript is required for the print function  

Purpose

Subroutine SSWRLSTRD reads lists that are any number of repetitions of an input item that contains multiple variables. SWR1 input items that use this subroutine are items 4, 6, 7a, 8a, 9a, 10, 11b, 11c, 12, 13c, and 14a.

Documentation

Hughes, J.D., Langevin, C.D., Chartier, K.L., and White, J.T., 2012, Documentation of the Surface-Water Routing (SWR1) Process for modeling surface-water flow with the U.S. Geological Survey Modular Ground-Water Model (MODFLOW-2005): U.S. Geological Survey Techniques and Methods, book 6, chap. A40 (Version 1.0), 113 p. https://pubs.er.usgs.gov/publication/tm6A40

Related Packages

Surface-Water Routing (SWR) process

Supported in

MODFLOW-NWT
MODFLOW-OWHM

Item 1 is optional

Data Set 1

[CTAG] [IUNIT] [CFNAME]

CTAG—a text keyword defining the location of the list for the specific input item. Valid values are INTERNAL, EXTERNAL, or OPEN/CLOSE. If CTAG is not specified, the list is read from the SWR1 input file and is equivalent to specifying CTAG to be INTERNAL.

IUNIT—an integer value that defines the unit number for the file containing the list for the specific input item. The name of the file associated with this file unit must be contained in the Name File, and its file type must be ‘DATA’ in the Name File. IUNIT is only specified if CTAG is EXTERNAL.

CFNAME—a text value that defines the name of the file containing the list for the specific input item. This file will be opened on unit 99 just before reading the list and closed immediately after the list is read. This file should not be included in the Name File. CFNAME is only specified if CTAG is OPEN/CLOSE.

Data Set 2

LIST—is the specified number of lines of data in which each line contains a specified number of variables. The number of fields varies according to which input item is calling this routine. For example, two fields (IRCHSTG and STAGE) are read in input item 14a.