Please enable JavaScript to view this site.

ModelMuse Help

Navigation: Online Guide to MODFLOW > Observation Process

STOB - Stream Observation Package

Scroll Prev Top Next More

Abbreviation in Name file

STOB

Purpose

The Stream Observation input file is to specify observations of flow through Stream boundaries for use in the Observation process.

Documentation

str6.pdf

release.txt

OBS.pdf

Related Packages

Stream Package

Observation Process input files

Supported in

MODFLOW-2000

MODFLOW-2005

MODFLOW-LGR

MODFLOW-CFP

MODFLOW-NWT

Other Notes

The Stream (STR) package must be used in models in which the Stream Observation input file is used.

Input Instructions

Input for the Observation Process STR Package is read from a file that is specified with "STOB" as the file type listed in the name file. Free format is used throughout.

Data Set 0

[#Text]

Item 0 is optional and can include as many lines as desired. Each line needs to begin with the “#” character in the first column.

Data Set 1

MODFLOW-2000:

NQST NQCST NQTST (free format)

MODFLOW-2005:

NQST NQCST NQTST IUSTOBSV [NOPRINT] (free format)

MODFLOW-CFP, MODFLOW-NWT, MODFLOW-OWHM, and MODFLOW-LGR:

NQST NQCST NQTST IUSTOBSV (free format)

Data Set 2

MODFLOW-2000:

TOMULTST  EVFST IOWTQST (free format)

MODFLOW-2005, MODFLOW-CFP, MODFLOW-NWT, MODFLOW-OWHM, and MODFLOW-LGR:

TOMULTST (free format)

Read items 3, 4, and 5 for each of NQST groups of cells for which stream observations are to be specified.

Data Set 3

NQOBST NQCLST (free format)

Data Set 4

MODFLOW-2000:

OBSNAM IREFSP TOFFSET HOBS STATISTIC STAT-FLAG PLOT-SYMBOL

MODFLOW-2005, MODFLOW-CFP, MODFLOW-NWT, MODFLOW-OWHM, and MODFLOW-LGR:

OBSNAM IREFSP TOFFSET FLWOBS

Read item 4 for each of NQOBST observation times for this group of cells. STATISTIC and STAT-FLAG are ignored if IOWTQST is greater than zero.

Data Set 5

SEGMENT REACH FACTOR (free format)

Read item 5 for each cell in this group; the number of cells is equal to the absolute value of NQCLST read in item 3.

Read items 6 and 7 if IOWTQST is greater than 0. Items 6 and 7 are only available in MODFLOW-2000.

Data Set 6

FMTIN IPRN (free format)

 

Data Set 7

WTQ(1,1), WTQ(1,2), WTQ(1,3), ... , WTQ(1,NQTST) (format: FMTIN)

WTQ(2,1), WTQ(2,2), WTQ(2,3), ... , WTQ(2,NQTST)

...

WTQ(NQTST,1), WTQ(NQTST,2), WTQ(NQTST,3), ... , WTQ(NQTST,NQTST)