[link or image removed] indicates that a reference has been removed from this document in order to prevent the exposure of internal resources.
GW1994.02 Guidance for the preparation, approval, and archiving of aquifer-test results
Analyses of aquifer tests to define the hydraulic characteristics of a specific aquifer or aquifer system are an integral part of our interpretive ground-water investigations. The results of these analyses are critical components of flow-system or solute-transport analyses and important to conclusions published in U.S. Geological Survey (USGS) reports. Consequently, reported aquifer characteristics such as hydraulic conductivity, transmissivity, storativity and other hydraulic characteristics derived from aquifer-test analyses must be
clearly documented and technically defensible. The purpose of this memorandum is to describe guidelines and procedures necessary to obtain approval for the results of aquifer tests analyzed by employees of the Water Resources Division (WRD) and to provide guidelines for archival of the test results.
BACKGROUND
According to WRD Publications Guide (Article 11.01.2) "....calculated hydraulic characteristics such as transmissivity, hydraulic conductivity, and storage coefficient, are interpretive and must be approved by the Director, unless cited from a Director- approved report." In a memorandum dated March 11, 1992, the Assistant Chief Hydrologist, Scientific Information Management, delegated authority to approve aquifer-test results to the Regional Hydrologists. Approval is required for all calculations of aquifer-hydraulic characteristics to be released to the general public, to cooperators, or published in or otherwise used to support the results of investigations reported in USGS-approved reports.
Estimates of aquifer-hydraulic characteristics commonly are obtained from "textbook" or published values for various lithologies. These are not considered calculations of aquifer characteristics and do not require approval under the terms of this memorandum. In addition, estimates of transmissivity determined on the basis of specific-capacity measurements do not require approval.
DOCUMENTATION, APPROVAL, AND ARCHIVAL OF AQUIFER-TEST RESULTS
While the USGS encourages the publication of aquifer-test results, it is not feasible to publish the data and graphical results for every test conducted. In all cases, either as part of a formal report or as a separate packet, aquifer-test results should be submitted to the Regional Ground-Water Specialist for review and subsequent approval by the Regional Hydrologist. The Regional Ground-Water Specialist reviews the report manuscript or aquifer-test packet to assess (1) that the report or packet contains the necessary data and related information to properly analyze the subject test(s), and (2) that the analyses and results are technically defensible.
Elements that typically should be submitted for review are listed below. These elements assume an aquifer test comprising a pumping well and one or more observation wells and should be modified as appropriate for other types of tests such as a single-well slug test. The eight elements are as follows.
1. A brief description of the test (this can be neatly hand written) which includes the purpose, date, test procedures, and methods of analysis of the results. Any unique or unusual features or problems related to the test or to the collection and analysis of test data should be described. A brief description of the assumptions used in analyzing the test results also should be included, as needed to clarify the test.
2. A sketch of the test site showing the distances from the pumped well to all observation wells and the location of any boundaries, streams, springs, ditches, pumping or flowing wells, or other features that possibly could influence test results. Where the test includes multiple wells, the sketch of the test site should be drawn to scale.
3. Description of test and observation well construction, including screened and open interval(s), casing and screen diameters, and location of filter pack and grouted intervals.
4. A description of the site hydrogeologic characteristics, including sections that show the major water- bearing and confining zones or units. The intervals of the pumping and observation wells that are screened or open should be depicted on the logs or sections.
5. Time-discharge records of the pumped well (all measurements, not just average discharge).
6. Water-level records and hydrographs showing pre-test trends and water levels during the pumping and recovery phases.
7. Description of methods and computations showing adjustments to drawdown for pre-test trends, adjustments of recovery for projected drawdown, or adjustments to account for extraneous effects not related to pumping or recovery, such as barometric and tidal effects or other interferences.
8. All plots of observed or adjusted drawdown or recovery data used to determine hydraulic characteristics, showing match points, when used, and computations.
It is recognized that in some cases it is not possible to provide a complete description of these eight elements. Investigators are encouraged to discuss their plans with the Regional Ground-Water Specialist to determine the requirements for a particular test packet or report before they forward it for review and approval.
A transmittal memorandum, indicating that the test results have been reviewed by the District or Area ground-water specialist or his or her designee, should be included with the test packet or report. This review should include at least some checking of the field data and a verification that the test results are appropriate, given the site hydrogeology, well construction, and test conditions and that the test results have been reviewed independently before being submitted for regional review and approval.
Following approval by the Regional Hydrologist, the packet or report will be returned to the originating District or Office where the hydraulic characteristics and related site and well data should be entered into the Ground-Water Site Inventory System or National Water Information System (NWIS) and the packet and associated information appropriately archived in a District "aquifer-test file." These archived aquifer-test files should include the draft-report routing sheet or packet-review transmittal memorandum. Districts also are encouraged to archive test analyses and results completed prior to this memorandum. The aquifer-test files will be reviewed as a routine part of District ground-water discipline reviews.
If computer software is used in the aquifer-test analysis, the policy outlined in Office of Ground Water Technical Memorandum 91.04, dated August 14, 1991, must be followed. This policy requires that the theoretical basis of the software be documented and that it be demonstrated that a test-data set can be correctly analyzed using the software. Submittal of a computer-software analysis does not eliminate the need for the information described in item element 8, above.
This memorandum discusses information needs in the context of single- or multiple-well aquifer tests. Aquifer characteristics also may be calculated by other methods, such as, determination of aquifer diffusivity from attenuation of a tidal pulse or flood wave through an aquifer, or using hydrograph-recession characteristics. The same review procedures should be followed for these types of analyses, and information in the report manuscript or packet must be adequate to enable reviewers to visualize the physical system, evaluate all data, verify all calculations, and assess that the methods and results are defensible.
Sincerely,
/s/ William M. Alley Chief, Office of Ground Water
Attachment
Distribution: A, B, S, FO, PO
BACKGROUND
According to WRD Publications Guide (Article 11.01.2) "....calculated hydraulic characteristics such as transmissivity, hydraulic conductivity, and storage coefficient, are interpretive and must be approved by the Director, unless cited from a Director- approved report." In a memorandum dated March 11, 1992, the Assistant Chief Hydrologist, Scientific Information Management, delegated authority to approve aquifer-test results to the Regional Hydrologists. Approval is required for all calculations of aquifer-hydraulic characteristics to be released to the general public, to cooperators, or published in or otherwise used to support the results of investigations reported in USGS-approved reports.
Estimates of aquifer-hydraulic characteristics commonly are obtained from "textbook" or published values for various lithologies. These are not considered calculations of aquifer characteristics and do not require approval under the terms of this memorandum. In addition, estimates of transmissivity determined on the basis of specific-capacity measurements do not require approval.
DOCUMENTATION, APPROVAL, AND ARCHIVAL OF AQUIFER-TEST RESULTS
While the USGS encourages the publication of aquifer-test results, it is not feasible to publish the data and graphical results for every test conducted. In all cases, either as part of a formal report or as a separate packet, aquifer-test results should be submitted to the Regional Ground-Water Specialist for review and subsequent approval by the Regional Hydrologist. The Regional Ground-Water Specialist reviews the report manuscript or aquifer-test packet to assess (1) that the report or packet contains the necessary data and related information to properly analyze the subject test(s), and (2) that the analyses and results are technically defensible.
Elements that typically should be submitted for review are listed below. These elements assume an aquifer test comprising a pumping well and one or more observation wells and should be modified as appropriate for other types of tests such as a single-well slug test. The eight elements are as follows.
1. A brief description of the test (this can be neatly hand written) which includes the purpose, date, test procedures, and methods of analysis of the results. Any unique or unusual features or problems related to the test or to the collection and analysis of test data should be described. A brief description of the assumptions used in analyzing the test results also should be included, as needed to clarify the test.
2. A sketch of the test site showing the distances from the pumped well to all observation wells and the location of any boundaries, streams, springs, ditches, pumping or flowing wells, or other features that possibly could influence test results. Where the test includes multiple wells, the sketch of the test site should be drawn to scale.
3. Description of test and observation well construction, including screened and open interval(s), casing and screen diameters, and location of filter pack and grouted intervals.
4. A description of the site hydrogeologic characteristics, including sections that show the major water- bearing and confining zones or units. The intervals of the pumping and observation wells that are screened or open should be depicted on the logs or sections.
5. Time-discharge records of the pumped well (all measurements, not just average discharge).
6. Water-level records and hydrographs showing pre-test trends and water levels during the pumping and recovery phases.
7. Description of methods and computations showing adjustments to drawdown for pre-test trends, adjustments of recovery for projected drawdown, or adjustments to account for extraneous effects not related to pumping or recovery, such as barometric and tidal effects or other interferences.
8. All plots of observed or adjusted drawdown or recovery data used to determine hydraulic characteristics, showing match points, when used, and computations.
It is recognized that in some cases it is not possible to provide a complete description of these eight elements. Investigators are encouraged to discuss their plans with the Regional Ground-Water Specialist to determine the requirements for a particular test packet or report before they forward it for review and approval.
A transmittal memorandum, indicating that the test results have been reviewed by the District or Area ground-water specialist or his or her designee, should be included with the test packet or report. This review should include at least some checking of the field data and a verification that the test results are appropriate, given the site hydrogeology, well construction, and test conditions and that the test results have been reviewed independently before being submitted for regional review and approval.
Following approval by the Regional Hydrologist, the packet or report will be returned to the originating District or Office where the hydraulic characteristics and related site and well data should be entered into the Ground-Water Site Inventory System or National Water Information System (NWIS) and the packet and associated information appropriately archived in a District "aquifer-test file." These archived aquifer-test files should include the draft-report routing sheet or packet-review transmittal memorandum. Districts also are encouraged to archive test analyses and results completed prior to this memorandum. The aquifer-test files will be reviewed as a routine part of District ground-water discipline reviews.
If computer software is used in the aquifer-test analysis, the policy outlined in Office of Ground Water Technical Memorandum 91.04, dated August 14, 1991, must be followed. This policy requires that the theoretical basis of the software be documented and that it be demonstrated that a test-data set can be correctly analyzed using the software. Submittal of a computer-software analysis does not eliminate the need for the information described in item element 8, above.
This memorandum discusses information needs in the context of single- or multiple-well aquifer tests. Aquifer characteristics also may be calculated by other methods, such as, determination of aquifer diffusivity from attenuation of a tidal pulse or flood wave through an aquifer, or using hydrograph-recession characteristics. The same review procedures should be followed for these types of analyses, and information in the report manuscript or packet must be adequate to enable reviewers to visualize the physical system, evaluate all data, verify all calculations, and assess that the methods and results are defensible.
Sincerely,
/s/ William M. Alley Chief, Office of Ground Water
Attachment
Distribution: A, B, S, FO, PO