Online Guide to MODFLOW-2005

Specified Head Boundaries

Hide Navigation Pane

Specified Head Boundaries

Previous topic Next topic No directory for this topic No expanding text in this topic  

Specified Head Boundaries

Previous topic Next topic Topic directory requires JavaScript JavaScript is required for expanding text JavaScript is required for the print function  

Specified heads can be set up in several ways.

In the Basic package, IBOUND is used to identify specified head boundaries and STRT gives the head at those boundaries.

The Time-Variant Specified-Head package can be used.

The Flow and Head Boundary package can be used.

Specified heads specified by the Time-Variant Specified-Head package override those specified by a combination of IBOUND and STRT in the Basic package.

Specified heads specified by the Flow and Head Boundary package override those specified either by a combination of IBOUND and STRT in the Basic package or by the Time-Variant Specified-Head package.