CRCH: Conduit Recharge Pane

  • Scroll to top of this topic Scroll to Top of Page

  • Print the current topic Print Topic

  • No expanding elements on this page Show/Hide Expanders

The CRCH: Conduit Recharge pane is on the MODFLOW Features tab of the Object Properties dialog box.

This pane is only visible if the Conduit Flow Process is selected and individual conduits are simulated, the Recharge package is selected and conduit recharge is selected.

The data that can be specified for the Conduit Recharge package are the Starting time, Ending time, and Recharge fraction. The Recharge fraction is the fraction of the recharge in a cell that should be diverted to a conduit node. It should be between 0 and 1.

Starting time and Ending time are explained in the help for the MODFLOW Features tab.

When conduit recharge is displayed by coloring the grid all the cells enclosed or intersected by the object will be colored even though only cells that are actually conduit nodes will have recharge diverted to them.