PROGRAMS AND PLANS--New Procedures for Examining Laboratory Codes and WATSTORE Codes In Reply Refer To: March 18, 1983 EGS-Mail Stop 412 QUALITY OF WATER BRANCH TECHNICAL MEMORANDUM NO. 83.11 Subject: PROGRAMS AND PLANS--New Procedures for Examining Laboratory Codes and WATSTORE Codes 1. New Procedures The Ouality of Water Branch, Analytical Services Coordinator, and Scientific Publications and Data Management are making available two new procedures for examining laboratory codes and WATSTORE codes. The first procedure, LABCODES, produces three sections of output: 1. A table of information about lab codes listed by lab-code number. 2. A table of information about lab codes listed by lab-code name (alphabetically). 3. A table of information about lab codes listed by WATSTORE parameter code. The information includes lab-code number, lab-code name, WATSTORE parameter code, TWRI method, lab cost, parameter calculation indicator, and laboratory section designation. To execute the procedure, LABCODES: //xxxxxxxx JOB (xxxxxxxxx, //PROCLIB DD DSN=WRD.PROCLIB,DISP=SHR // EXEC LABCODES The second procedure, QPARM, produces two sections of output: 1. A table of information about WATSTORE parameter codes listed by code number. 2. A table of information about WATSTORE parameter codes listed by code name (alphabetically). The information includes WATSTORE parameter code number, name, significant figures, and special rounding codes. To execute the procedure, QPARM: //xxxxxxxx JOB (xxxxxxxxx, //PROCLIB DD DSN=WRD.PROCLIB,DISP=SHR // EXEC QPARM 2. WATSTORE Parameter Codes Users of the Water-Quality Data-Processing System should be made aware of the following administrative and descriptive WATSTORE parameter codes: WATSTORE Code Description 00008 Sample Number 00022 Length of Exposure, Days 00027 Collecting Agency (required for all new analyses) 00028 Analyzing Agency (required for all new analyses) 00029 Project Number 00063 Number of Sampling Points 00115 Sample Treatment 00206 Collector Area, Wet, Sq. Meters 00207 Collector Area, Dry, Sq. Meters 32000 Sample Size, Liters 32002 Sample Size, Milliliters 71995 Water Use, Primary 71996 Water Use, Secondary 71997 Water Use, Tertiary 71998 Water Use, Quaternary 71999 Sample Purpose 72005 Sample Source 72006 Sample Condition 74200 Sample Preservation Method 81352 Filter Pore Size 82075 Rinse Water Amount, Liters 82076 Exposure Area, Sq. Centimeters 82309 Contamination Source 82373 Sample Frequency 82398 Sample Method 84060 Topography-Physiographic Setting R. J. Pickering WRD Distribution: A, B, S, PO, FO Key Words: water quality, WATSTORE, data handling This memorandum does not supersede any previous memorandum