  <xsd:element name="DriftCheckDissolvedOxygenReading">
    <xsd:annotation>
      <xsd:documentation>
        <Definition>The calibration drift check of a water quality monitor sensor for disolved oxygen, during a site visit.</Definition>
      </xsd:documentation>
    </xsd:annotation>
    <xsd:complexType>
      <xsd:sequence>
        <xsd:element name="CalibrationCode" type="ReferenceListCodeType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The Code indicating whether the reading is for calibration or recalibration.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="MethodCode" type="ReferenceListCodeType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The Code indicating the type of DO calibration method used.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="ReadingDateTime" type="DateTimeWithDatum">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The date and time of the disolved oxygen sensor check or calibration reading.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="TemperatureMeasure" type="IEEE754UncertaintyFloatValueType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The water temperature measured during the disolved oxygen check or calibration. The default units is celsius.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="BarometricMeasure" type="IEEE754UncertaintyFloatValueType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The barometric pressure measured during the disolved oxygen check or calibration, in inches of mercury.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="DissolvedOxygenTableMeasure" type="IEEE754FloatValueType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The dissolved oxygen table value (from temperature and barometric pressure) for the dissolved oxygen calibration check reading, in milligrams per liter.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="SalinityCorrectionFactor" type="IEEE754FloatValueType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The salinity correction factor for the dissolved oxygen calibration check or recalibration reading.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="DissolvedOxygenMeasure" type="IEEE754UncertaintyFloatValueType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The dissolved oxygen value for the dissolved oxygen calibration check or recalibration reading.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="ErrorMeasure" type="IEEE754FloatValueType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The percent error between the disolved oxygen standard and the check or calibration reading.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
        <xsd:element name="DissolvedOxygenZeroMeasure" type="IEEE754UncertaintyFloatValueType">
          <xsd:annotation>
            <xsd:documentation>
              <Definition>The dissolved oxygen value in zero dissolved oxygen solution for the dissolved oxygen calibration check reading, in milligrams per liter.</Definition>
            </xsd:documentation>
          </xsd:annotation>
        </xsd:element>
      </xsd:sequence>
    </xsd:complexType>
  </xsd:element>
</xsd:schema>